Skip to content
Commit b84bd27f authored by Benjamin Tissoires's avatar Benjamin Tissoires Committed by Jiri Kosina
Browse files

HID: hid-multitouch: fix broken eGalax



Since the inclusion of eGalax devices in 2.6.39, I've got some
bug reports for 480d and other devices.
The problem lies in the reports descriptors: eGalax supports both
pen and fingers, and so the reports descriptors contained both.
But hid-multitouch relies on them to detect the last item in each
field to send the multitouch events. In 480d, the last item is not
Y as it should but Pressure. That means that the fields are not
aligned and X,Y are at 0,0 (the other touch coordinates of the report).

With this patch, the detection is made only when the field ContactID
has been detected inside the collection.

There is still a problem with the detections of the range as stylus
and fingers may not have the same min/max, but it's a start.

Signed-off-by: default avatarBenjamin Tissoires <benjamin.tissoires@enac.fr>
Reviewed-by: default avatarHenrik Rydberg <rydberg@euromail.se>
Signed-off-by: default avatarJiri Kosina <jkosina@suse.cz>