Skip to content
Commit 8f21d8e9 authored by Pali Rohár's avatar Pali Rohár Committed by Greg Kroah-Hartman
Browse files

i8k: Autodetect fan RPM multiplier



This patch adds new function i8k_get_fan_nominal_speed() for doing SMM call
which will return nominal fan RPM for specified fan speed. It returns nominal
RPM value at which fan operate when speed (0, 1, 2, 3) is set. It looks like
RPM value is not accurate, but still provides very useful information.

New function i8k_get_fan_nominal_speed() is used for determinate if fan
multiplier is 1 or 30. If function for maximal fan value success and returned
RPM value too high (above 30000) then fan multiplier is set to 1. Otherwise
multiplier is not changed and default value 30 is used.

Signed-off-by: default avatarPali Rohár <pali.rohar@gmail.com>
Tested-by: default avatarPali Rohár <pali.rohar@gmail.com>
Tested-by: default avatarGabriele Mazzotta <gabriele.mzt@gmail.com>
Reviewed-by: default avatarGuenter Roeck <linux@roeck-us.net>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 7f69fb03