HID: wacom: Ignore contacts in excess of declared contact count
The reports sent from some touch devices (e.g. the Cintiq 24HDT) contain junk data in the contact slots which follow the final "valid" contact. To avoid forwarding it to usrspace, we store the reported contact count during the pre-process phase and then only process that many contacts. If a device sends its contacts across multiple reports (what Microsoft refers to as "hybrid" mode) then the contact count will be zero for reports other than the first. Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.com>