[PATCH] x86: increase interrupt vector range
Remove the limit of 256 interrupt vectors by changing the value stored in orig_{e,r}ax to be the complemented interrupt vector. The orig_{e,r}ax needs to be < 0 to allow the signal code to distinguish between return from interrupt and return from syscall. With this change applied, NR_IRQS can be > 256. Xen extends the IRQ numbering space to include room for dynamically allocated virtual interrupts (in the range 256-511), which requires a more permissive interface to do_IRQ. Signed-off-by: Ian Pratt <ian.pratt@xensource.com> Signed-off-by: Christian Limpach <Christian.Limpach@cl.cam.ac.uk> Signed-off-by: Chris Wright <chrisw@sous-sol.org> Signed-off-by: Rusty Russell <rusty@rustcorp.com.au> Cc: "Protasevich, Natalie" <Natalie.Protasevich@UNISYS.com> Cc: Andi Kleen <ak@muc.de> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>