Commit 0873a5ae authored by Erik J. Staab's avatar Erik J. Staab Committed by Takashi Iwai
Browse files

ALSA: oxygen: fix analog capture on Claro halo cards



On the HT-Omega Claro halo card, the ADC data must be captured from the
second I2S input.  Using the default first input, which isn't connected
to anything, would result in silence.

Signed-off-by: default avatarErik J. Staab <ejs@insightbb.com>
Signed-off-by: default avatarClemens Ladisch <clemens@ladisch.de>
Cc: <stable@kernel.org>
Signed-off-by: default avatarTakashi Iwai <tiwai@suse.de>
parent b30a3f62