battery: fix ordering of ICL/FCC configuration
Current parallel design has fixed order of configuring
ICL/FCC between main and parallel charger, this could
lead to a situation where total(main + parallel) ICL/FCC
goes beyond maximum configured value.
Fix this by dynamic ordering of ICL/FCC between main and
parallel based on AICL change.
CRs-Fixed: 2148379
Change-Id: Ia1ff7093d1de9205ce8072760c80ba0a58638462
Signed-off-by: Ashay Jaiswal <ashayj@codeaurora.org>