Commit 086235d0 authored by Finn Thain's avatar Finn Thain Committed by bgman111111
Browse files

powerpc/tau: Use appropriate temperature sample interval



[ Upstream commit 66943005cc41f48e4d05614e8f76c0ca1812f0fd ]

According to the MPC750 Users Manual, the SITV value in Thermal
Management Register 3 is 13 bits long. The present code calculates the
SITV value as 60 * 500 cycles. This would overflow to give 10 us on
a 500 MHz CPU rather than the intended 60 us. (But according to the
Microprocessor Datasheet, there is also a factor of 266 that has to be
applied to this value on certain parts i.e. speed sort above 266 MHz.)
Always use the maximum cycle count, as recommended by the Datasheet.

Fixes: 1da177e4 ("Linux-2.6.12-rc2")
Signed-off-by: default avatarFinn Thain <fthain@telegraphics.com.au>
Tested-by: default avatarStan Johnson <userm57@yahoo.com>
Signed-off-by: default avatarMichael Ellerman <mpe@ellerman.id.au>
Link: https://lore.kernel.org/r/896f542e5f0f1d6cf8218524c2b67d79f3d69b3c.1599260540.git.fthain@telegraphics.com.au


Signed-off-by: default avatarSasha Levin <sashal@kernel.org>
parent 3246aed1