clocksource: Avoid selecting mult values that might overflow when adjusted
For some frequencies, the clocks_calc_mult_shift() function will unfortunately select mult values very close to 0xffffffff. This has the potential to overflow when NTP adjusts the clock, adding to the mult value. This patch adds a clocksource.maxadj value, which provides an approximation of an 11% adjustment(NTP limits adjustments to 500ppm and the tick adjustment is limited to 10%), which could be made to the clocksource.mult value. This is then used to both check that the current mult value won't overflow/underflow, as well as warning us if the timekeeping_adjust() code pushes over that 11% boundary. v2: Fix max_adjustment calculation, and improve WARN_ONCE messages. v3: Don't warn before maxadj has actually been set CC: Yong Zhang <yong.zhang0@gmail.com> CC: David Daney <ddaney.cavm@gmail.com> CC: Thomas Gleixner <tglx@linutronix.de> CC: Chen Jie <chenj@lemote.com> CC: zhangfx <zhangfx@lemote.com> CC: stable@kernel.org Reported-by: Chen Jie <chenj@lemote.com> Reported-by: zhangfx <zhangfx@lemote.com> Tested-by: Yong Zhang <yong.zhang0@gmail.com> Signed-off-by: John Stultz <john.stultz@linaro.org>