Skip to content
Commit 869c6a3e authored by Lothar Waßmann's avatar Lothar Waßmann Committed by Wolfram Sang
Browse files

i2c: mxs: fix broken timing calculation



The timing calculation is rather bogus and gives extremely wrong
results for higher frequencies (on an i.MX28). E.g. instead of 400 kHz
I measured 770 kHz.

Implement a calculation that adheres to the I2C spec and gives exact
results for I2C frequencies from 12.56 kHz to 960 kHz.

Also the bus_free and leadin parameters are programmed according to
the I2C spec for standard and fast mode.

This was tested on a Ka-Ro TX28 module with a DS1339, TSC2007, PCA9554
and SGTL5000 client.

Signed-off-by: default avatarLothar Waßmann <LW@KARO-electronics.de>
Acked-by: default avatarMarek Vasut <marex@denx.de>
[wsa: patch fixes whitespace issue, too]
Signed-off-by: default avatarWolfram Sang <wsa@the-dreams.de>
parent b7d12a86