Skip to content
Commit 87aa6300 authored by Gabriele A. Trombetti's avatar Gabriele A. Trombetti Committed by NeilBrown
Browse files

md/raid6: Fix raid-6 read-error correction in degraded state



Fix: Raid-6 was not trying to correct a read-error when in
singly-degraded state and was instead dropping one more device, going to
doubly-degraded state. This patch fixes this behaviour.

Tested-by: default avatarJanos Haar <janos.haar@netcenter.hu>
Signed-off-by: default avatarGabriele A. Trombetti <g.trombetti.lkrnl1213@logicschema.com>
Reported-by: default avatarJanos Haar <janos.haar@netcenter.hu>
Signed-off-by: default avatarNeilBrown <neilb@suse.de>
Cc: stable@kernel.org
parent 722154e4
Loading
Loading
Loading
Loading
0% Loading or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment