md/raid6: Fix raid-6 read-error correction in degraded state
Fix: Raid-6 was not trying to correct a read-error when in singly-degraded state and was instead dropping one more device, going to doubly-degraded state. This patch fixes this behaviour. Tested-by: Janos Haar <janos.haar@netcenter.hu> Signed-off-by: Gabriele A. Trombetti <g.trombetti.lkrnl1213@logicschema.com> Reported-by: Janos Haar <janos.haar@netcenter.hu> Signed-off-by: NeilBrown <neilb@suse.de> Cc: stable@kernel.org
Loading
Please register or sign in to comment