ARM: 7008/1: alignment: Make SIGBUS sent to userspace POSIXly correct
With the UM_SIGNAL alignment fault mode, no siginfo structure is passed to userspace. POSIX specifies how siginfo_t should be populated for alignment faults, so this patch does just that: * si_signo = SIGBUS * si_code = BUS_ADRALN * si_addr = misaligned data address at which access was attempted Signed-off-by: Dave Martin <dave.martin@linaro.org> Acked-by: Nicolas Pitre <nicolas.pitre@linaro.org> Acked-by: Kirill A. Shutemov <kirill@shutemov.name> Reviewed-by: Will Deacon <will.deacon@arm.com> Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>