Commit bf00ca35 authored by Nishanth Menon's avatar Nishanth Menon Committed by Mark Brown
Browse files

regulator: ti-abb: Fix bias voltage glitch in transition to bypass mode



As documented in Application Note SWPA117 v2.1(NDA), LDO override has a
requirement that when switching from Bias active + override active
mode(FBB/RBB) to Bypass(nominal) mode, LDO reset must be performed
*after* LDO transitions to Bypass(nominal) mode.

The same rule in reverse applies when switching from a ABB bypass mode
to ABB enabled - LDO override *must* be performed prior to transition to
required ABB mode, if we do not do that, the same glitch takes place.

Currently while transitioning to ABB bypass, we reset the LDO overide
prior to the transition which causes a few milliseconds where ABB LDO
voltage could go all the way to 800mV(based on SoC process node),
during this period, the delta voltage between VDD rail and VBB rail
could cause the system to improperly function.

Signed-off-by: default avatarNishanth Menon <nm@ti.com>
Signed-off-by: default avatarMark Brown <broonie@linaro.org>
Cc: stable@vger.kernel.org
parent 4a10c2ac