Skip to content
Commit 603ecce9 authored by Manoj N. Kumar's avatar Manoj N. Kumar Committed by Martin K. Petersen
Browse files

cxlflash: Fix to avoid unnecessary scan with internal LUNs



When switching to the internal LUN defined on the
IBM CXL flash adapter, there is an unnecessary
scan occurring on the second port. This scan leads
to the following extra lines in the log:

Dec 17 10:09:00 tul83p1 kernel: [ 3708.561134] cxlflash 0008:00:00.0: cxlflash_queuecommand: (scp=c0000000fc1f0f00) 11/1/0/0 cdb=(A0000000-00000000-10000000-00000000)
Dec 17 10:09:00 tul83p1 kernel: [ 3708.561147] process_cmd_err: cmd failed afu_rc=32 scsi_rc=0 fc_rc=0 afu_extra=0xE, scsi_extra=0x0, fc_extra=0x0

By definition, both of the internal LUNs are on the first port/channel.

When the lun_mode is switched to internal LUN the
same value for host->max_channel is retained. This
causes an unnecessary scan over the second port/channel.

This fix alters the host->max_channel to 0 (1 port), if internal
LUNs are configured and switches it back to 1 (2 ports) while
going back to external LUNs.

Signed-off-by: default avatarManoj N. Kumar <manoj@linux.vnet.ibm.com>
Acked-by: default avatarMatthew R. Ochs <mrochs@linux.vnet.ibm.com>
Reviewed-by: default avatarUma Krishnan <ukrishn@linux.vnet.ibm.com>
Signed-off-by: default avatarMartin K. Petersen <martin.petersen@oracle.com>